Climate impact

Salt air and the climate

Salt air is not a local nuisance. It affects outdoor equipment on every ocean coastline, island, and harbor city.

A global problem

An analysis of Oak Ridge National Laboratory population data by Cosby and Lebakula finds that about 15% of the world’s people live within 10 km of the coast and about 29% within 50 km. Wherever air conditioning, refrigeration, and heating equipment sits in that salty air, it corrodes faster.

Why refrigerant matters

Air conditioners, heat pumps, and refrigeration systems run on refrigerants, and many are potent greenhouse gases. Global warming potential (GWP) is a score that compares how much a gas warms the planet against carbon dioxide, over 100 years. R-410A, the refrigerant used in most residential air conditioners installed between 2010 and 2024, has 2,088 times the global warming potential of carbon dioxide. In plain terms, every pound of R-410A released into the atmosphere has the equivalent warming impact of releasing 2,088 pounds of CO₂ over a 100-year period. Newer refrigerants are lower: R-32 is 675 and R-454B is about 465. Phase-down rules are changing what new equipment uses, but millions of R-410A systems remain in service.

Two outdoor air conditioning condensers on a coastal home, covered in rust and salt residue

From corrosion to leaks

Corrosion is a leading cause of coil failure. Salt water and corrosive air eat through the thin metal tubing that holds refrigerant, and a pinhole lets refrigerant escape. HVAC manufacturers and trade publications list corrosion among the main reasons coils fail. We believe coastal systems are especially exposed, and independent testing is planned to measure how much salt protection reduces leaks.

What an escape is worth

A typical home system holds roughly 6 to 10 pounds of refrigerant, and EPA puts the U.S. average near 10. As an example, 8 pounds of R-410A is about 16,700 pounds of CO2 equivalent, or 7.6 metric tons, if all of it escapes. The California Air Resources Board estimates that about 80% of a system’s remaining refrigerant is released when equipment is retired, while EPA estimates 20 to 40%. Keeping equipment sealed and in service longer delays that release.

Chlorine does the same damage

Facilities with heavy chlorine exposure, such as waterparks and aquatic centers, can see early equipment failure from chlorine corrosion, much like salt air on the coast. The Guardian is designed to protect those systems as well.

What is proven, and what we are testing

The figures above are published estimates, not Salt-Safe test results. Our field prototypes are serviced every two weeks, and independent lab testing is next; we plan to publish the results.

Preventing corrosion means more than protecting equipment. It means protecting the environment.

Sources: Cosby and Lebakula, coastal population analysis using Oak Ridge National Laboratory data; U.S. EPA fact sheet on HFCs in residential and light commercial air conditioning; U.S. EPA Technology Transitions GWP reference table; California Air Resources Board estimates as summarized in ACEEE and DNV, Refrigerants, Taking the Chill Out of Heat Pumps; Bosch Home Comfort heat pump coil corrosion service bulletin.

The numbers at a glance

Climate impact in one view

Infographic summarizing the climate impact of refrigerant leaks from corroded coastal equipment